| Availability: | |
|---|---|
| Quantity: | |
Intuitive Touch Display: Features a colorful touch LCD screen for real-time data tracking, housed in an IP66 robust casing for superior weather resistance.
Seamless AC Coupling: Perfectly retrofits your existing solar system into a smart hybrid energy storage system via efficient AC coupling.
Diesel Generator Support: Designed to work flawlessly with diesel generators, capturing and storing energy to ensure continuous power during long outages.
Customizable Energy Strategy: Offers 6 configurable time periods for battery charging/discharging to optimize peak-shaving and valley-filling strategies.
Massive Scalability: Connect up to 16 inverters in parallel for large-scale on-grid and off-grid operations, with support for multiple battery strings.
Model | LD06H-SM-3K6-EP-D | LD06H-SM-5K-EP-D | LD06H-SM-6K-EP-D |
Battery Input Data | |||
Battery Type | Lead-acid or Lithium-ion | ||
Battery Voltage Range(V) | 40-60 | ||
Max. Charging Current(A) | 90 | 120 | 135 |
Max. Discharging Current(A) | 90 | 120 | 135 |
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | ||
Number of Battery Input | 1 | ||
PV String Input Data | |||
Max. PV access Power(W) | 7200 | 10000 | 12000 |
Max. PV Input Power(W) | 5760 | 6500 | 9600 |
Max. PV Input Voltage(V) | 500 | ||
Start-up Voltage(V) | 125 | ||
PV Input Voltage Range(V) | 125-500 | ||
MPPT Voltage Range(V) | 150~425 | ||
Full Load MPPT Voltage Range(V) | 300~425 | ||
Rated PV Input Voltage(V) | 370 | ||
Max. Operating PV Input Current(A) | 18+18 | ||
Max. Input Short-Circuit Current(A) | 27+27 | ||
No. of MPP Trackers/No. of Strings MPP Tracker | 2/1+1 | ||
Max. Inverter Backfeed Current to The Array | 0 | ||
AC Input Data | |||
Rated AC Input Active Power(W) | 3600 | 5000 | 6000 |
Max. AC Input Active Power(W) | 3960 | 5500 | 6600 |
Peak Power(off grid)(W) | 2 times of rated power, 10s | ||
Rated AC Input/Output Current(A) | 16.4/15.7 | 22.8/21.8 | 27.3/26.1 |
Max. Rated AC Input/Output Current(A) | 18/17.3 | 25/24 | 30/28.7 |
Max. Continuous AC Passthrough(grid to load)(A) | 35 | 40 | |
Max. Output Fault Current(A) | 36 | 50 | 60 |
Max. Output Overcurrent Protection(A) | 70 | 80 | |
Rated Input Voltage/Range(V) | 220V/230V 0.85Un-1.1Un | ||
Grid Connection Form | L+N+PE | ||
Rated Input Grid Frequency/Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz | ||
Total Harmonic Distortion(THDi) | <3% (of nominal power) | ||
DC Injection Current | <0.5% ln | ||
Efficiency | |||
Max. Efficiency | 97.60% | ||
Euro Efficiency | 96.50% | ||
MPPT Efficiency | >99% | ||
Equipment Protection | |||
DC Polarity Reverse Connection Protection | Yes | ||
AC Output Overcurrent Protection | Yes | ||
AC Output Overvoltage Protection | Yes | ||
AC Output Short Circuit Protection | Yes | ||
Thermal Protection | Yes | ||
DC Terminal Insulation Impedance Monitoring | Yes | ||
DC Component Monitoring | Yes | ||
Ground Fault Current Monitoring | Yes | ||
Arc fault circuit interrupter(AFCI) | Optional | ||
Power Network Monitoring | Yes | ||
Island Protection Monitoring | Yes | ||
Earth Fault Detection | Yes | ||
DC Input Switch | Yes | ||
Overvoltage Load Drop Protection | Yes | ||
Residual Current (RCD) Detection | Yes | ||
Surge Protection Level | Type II(DC) / Type II(AC) | ||
Interface | |||
Display | LCD+LED | ||
Communication Interface | RS232, RS485, CAN | ||
Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN(optional) | ||
General Data | |||
Operating Temperature Range | -40 to +60℃, >45℃ Derating | ||
Permissible Ambient Humidity | 0-100% | ||
Permissible Altitude | 2000m | ||
Noise(dB) | <30 dB | ||
Ingress Protection(IP) Rating | IP 66 | ||
Inverter Topology | Non-Isolated | ||
Over Voltage Category | OVC II(DC), OVC III(AC) | ||
Weight(kg) | 19 | ||
Cabinet size(mm)(W×H×D)(Excluding connectors and brackets) | 340×475×248 | ||
Warranty | 5 Years/10 Years | ||
Type of Cooling | Natural Cooling | ||
Grid Regulation | IEC 61727,IEC 62116,EN 50549 | ||
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||