| Availability: | |
|---|---|
| Quantity: | |
High-Voltage Efficiency: Designed to work perfectly with high-voltage batteries, minimizing energy loss during conversion and delivering superior overall system efficiency.
100% Unbalanced Output: Highly adaptable 100% unbalanced output capability, providing up to 50% of the rated power on a single phase to tackle diverse loads.
Optimized 50A Current: Offers a reliable 50A maximum charging and discharging current specifically tuned for high-voltage commercial battery racks.
AC Coupling Ready: Streamlines the retrofitting of existing solar installations, transforming them into resilient energy storage networks.
Generator Energy Recovery: Connects directly to diesel generators, ensuring that all excess produced energy is stored rather than wasted.
6-Period Time of Use: Program up to 6 different time schedules to charge the battery during cheap utility hours and discharge during expensive peaks.
10-Unit Parallel Scaling: Secure your future energy needs by paralleling up to 10 units for large-scale on-grid or off-grid operations.
Model | LD01H-TH-0080H-EP | LD01H-TH-0100H-EP | LD01H-TH-0150H-EP | LD01H-TH-0200H-EP | LD01H-TH-0250H-EP |
Battery | |||||
Battery Type | Lithium-ion | ||||
Battery Voltage Range (V) | 160-700 | ||||
Max. Charging Current (A) | 37 | 50 | |||
Max. Discharging Current (A) | 37 | 50 | |||
Number of Battery Input | 1 | ||||
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | ||||
PV string Input Data | |||||
Max. DC Input Power (W) | 10400 | 13000 | 19500 | 26000 | 32500 |
Max. DC Input Voltage (V) | 1000 | ||||
Start-up Voltage (V) | 180 | ||||
MPPT Range (V) | 150-850 | ||||
Rated DC Input Voltage (V) | 600 | 700 | |||
PV Input Current (A) | 20+20 | 26+26 | |||
Max. PV Isc (A) | 30+30 | 39+39 | |||
No.of MPPT Trackers | 2 | ||||
No.of Strings per MPPT Tracker | 1+1 | 2+2 | |||
AC Input/Output Data | |||||
Rated AC Output Power (W) | 8000 | 10000 | 15000 | 20000 | 25000 |
Max. AC Output Power (W) | 8800 | 11000 | 16500 | 22000 | 27500 |
AC Input/Output Rated Current(A) | 12.2/11.6 | 15.2/14.5 | 22.8/21.8 | 30.4/29.0 | 37.9/36.3 |
Max.AC Input/Output Current(A) | 13.4/12.8 | 16.7/16 | 25.0/24.0 | 33.4/31.9 | 41.7/39.9 |
Max. Three-phase Unbalanced Output Current (A) | 18 | 22 | 30 | 35 | 41.7 |
Max. Continuous AC Passthrough (A) | 40 | 40 | 80 | 80 | 80 |
Peak Power (Off Grid) | 1.5 times of rated power, 10 S | ||||
Generator Input/Smart Load/AC Couple Current (A) | 12.2/40/12.2 | 15.2/40/15.2 | 22.8/80/22.8 | 30.4/80/30.4 | 37.9/80/37.9 |
Power Factor | 0.8 leading - 0.8 lagging | ||||
Output Frequency and Voltage | 50/60Hz; 3L/N/PE 220/380Vac, 230/400Vac | ||||
Grid Type | Three Phase | ||||
Total Harmonic Distortion(THDi) | <3% | ||||
Efficiency | |||||
Max. Efficiency | 97.60% | ||||
Euro Efficiency | 97.00% | ||||
MPPT Efficiency | 99.90% | ||||
Protection | |||||
Anti-islanding Protection | Yes | ||||
PV String Input Reverse Polarity Protection | Yes | ||||
Insulation Resistor Detection | Yes | ||||
Residual Current Monitoring Unit | Yes | ||||
Output Over Current Protection | Yes | ||||
Output Shorted Protection | Yes | ||||
Surge Protection | Yes | ||||
Arc Fault Circuit Interruption (AFCI optional) | Yes | ||||
Over Voltage Protection | Yes | ||||
Certifications and standards | |||||
Grid Regulation | IEC61727/62116,EN50549-1 | ||||
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||||
General Data | |||||
Operating Temperature Range (℃) | –25 °C ~ +60 °C, > 45℃ Derating | ||||
Cooling | Intelligent Air Cooling | ||||
Noise (dB) | <55 dB | ||||
Communication with BMS | CAN | ||||
Monitoring mode | WIFI,APP | ||||
Size (WxHxD mm) | 456W×566H×255D (Excluding Connectors and Brackets) | ||||
Weight (kg) | 30 | ||||
Ingress Protection | IP66 | ||||
Installation Style | Wall-mounted | ||||
Warranty | 5 Years (10 Years Optional) | ||||